Product Information
APC SURTRK4 gives performance power protection with scalable runtime for space-constrained server rooms, and voice and data networks.
- Heavy duty design
The Vault Lock's heavy duty hardened steel construction provides the highest degree of portable tampering protection available on the market. - Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overloads condition or fault. - Scalable runtime
It allows additional run time to be quickly added as needed. - Intelligent battery management
It maximizes battery performance, life, and reliability through intelligent, precision charging. - Hot-swappable batteries
It ensures clean, uninterrupted power to protected equipment while batteries are being replaced. - Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power. - Temperature-compensated battery charging
It prolongs battery life by regulating the charge voltage according to battery temperature. - Network manageable
It provides remote management of the UPS over the network. - InfraStruXure manager compatible
Enables centralized management via the APC InfraStruXure manager. - LED status indicators
Quickly understand unit and power status with visual indicators. - Serial connectivity
It provides management of the UPS via a serial port. - Plug-and-Play external batteries
It ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. - Rack/tower convertible
It protects the initial investment in the UPS when migrating from tower to rack-mount environment. - Flash-upgradeable firmware
Easy implementation of new firmware upgrades. - Serviceability user-replaceable batteries
It increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR). - Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced. Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement. - Disconnected battery notification
It warns when a battery is not available to provide backup power. - Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. - Frequency and voltage regulation
It gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances. - Input power factor correction
It minimizes installation costs by enabling the use of smaller generators and cabling. - Generator compatible
It ensures clean, uninterrupted power to the loads in the event of an extended power outage. - Cold-start capable
It provides temporary battery power when the utility power is out. - Resettable circuit breakers
It enables a quick recovery from overload events. - Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.